CO2 Sensor CM1106-C | |
---|---|
Operating principle | Laser scattering |
Measurement range | 0~30,000μg/m³ |
Accuracy | PM10: ≤100μg/m³: ±15μg/m³, 100~1000μg/m³: ±15%Reading TSP (Note 1): ≤100μg/m³: ±20μg/m³, 100~1000μg/m³: ±20%Reading Condition: 0℃~40℃, 50±10%RH, calibration instrument: Met One |
Time to first reading | ≤ 8s |
Data refresh time | 1 second |
Sampling flow rate | Recommend 1 L/min |
Working condition | -30°C ~ 70°C,0-95%RH (non-condensing) |
Storage condition | -40°C ~ 85°C, 0-95%RH (non-condensing) |
Power supply | DC 5V±0.1V, ripple wave < 50mV |
Working current | < 150mA |
Standby current | < 25mA |
Dimensions | W82*H40.2*D26.3 mm |
Digital output | UART_TTL/I²C(3.3V/5V) |
Life time | > 5 years |
You can contact Cubic by telephone, mail or email , or you can submit an online Request for Quotation Form.
Email: info@gassensor.com.cn